Modular ISO8 SUSQ195 Laboratory Cleanroom HEPA Filter 3843m3/H

Guangzhou Anlai Airtech Co.,Ltd

Modular ISO8 SUSQ195 Laboratory Cleanroom HEPA Filter 3843m3/H

Brand Name : anlaitech

Model Number : AL-MODULAR CLEAN ROOM

Certification : CE , FAT, CLASS REPORT

Place of Origin : CHINA

Product name : Air Clean Room Clean Booth,Modular clean room,Class 100 Clean Room,Cleanroom,Portable Modular Clean Room Clean Booth With Hepa Filter

Material : Stainless Steel,Stailess Steel SUS304/201/Q195 /galvanized Sheet,sandwich panel,fire-proof),laminated board(scratch-proof

Application : 100 Lab / Laboratory Clean Room,Pharmaceutical,Chemical Lab,Electronic plant,Hospital

Name : Modular ISO8 SUSQ195 Laboratory Cleanroom HEPA Filter 3843m3/H

Type : Clean Room Booth,Modular Designs,cleanroom,Class B-D

Usage : Air Purification System,Pharmaceutical factory or laboratory,Dust Free Working for lcd glass oca laminating,Laborotory,clean requirement

Contact Now

ISO 5-8 Modular Laboratory Clean Room / Cleanroom

A clean room is an enclosed area employing control over the particulate matter in the air with temperature, humidity and pressure control as required. To meet the requirements of a 'clean room' as defined by generally accepted standards, all clean rooms must not exceed a particulate count as specified in the air cleanliness class. The IS Med Specialties (ISM) clean room is regulated to the Class 100,000 standard; meaning that the particle count inside does not exceed 100,000 particles per cubic foot. To provide a little background, the U.S. Federal Government established standards that were applied throughout the world (such as Class 100,000). More recently, global clean room classifications and standards have been adopted by the International Standards Organization (ISO). The Class 100,000 clean room is equivalent to an ISO 8 clean room standard.

A clean room is built in a contained space and controls environmental parameters such as humidity, pressure and temperature. The key component is the High Efficiency Particulate Air (HEPA) filter that is used to trap particles that are as small as 0.3 micron in size. HEPA filters are essential in providing contamination control.

MODEL
INNER size(W*L*H)mm
Air flow (m3/h)
CLEAN CLASS
SHIPPING
ALCS10*20
3050*6000*2500
2745
ISO7
LCL
ALCS14*20
4270*6000*2500
3843
ISO7
LCL
ALCS20*30
6000*9150*2500
8235
ISO7
20GP
ALCS20*50
6000*12800*2500
11520
ISO7
20GP
ALCS20*50
6000*15200*2500
13680
ISO7
20GP
ALCS26*42
8000*12800*2500
15360
ISO7
20GP
ALCS26*60
8000*15200*2500
18240
ISO7
20GP
ALCS30*65
9150*18300*2500
25110
ISO7
40GP
ALCS30*80

9150*24300*2500
33350
ISO7
40GP

HEPA Air Filtration in Modular Cleanrooms


Because the contained space of a modular clean room is intended to reduce particulate contamination, HEPA air filters are key to their performance. All the air delivered into a modular clean room passes through one or more High Efficiency Particulate Air filters, which trap any particles larger than 0.3 microns in size. For applications that require even greater cleanliness, ULPA (Ultra Low Particulate Air) filters that trap particles as small as 0.12 microns can be used.

Filtered air is supplied from overhead and, in most cases, passes out of the cleanroom via low wall vents. Single pass modular cleanrooms simply pull air in through the ceiling and exhaust it out; recirculating modular cleanrooms recycle the exhaust air back into the filter in a process of continuous circulation. Each design provides different benefits, and can impact other environmental parameters, such as temperature, humidity, and pressure.

What rules do employees have to follow to avoid contamination?


Employees are provided with gloves, gowns, masks and booties. Employees are not to wear perfumes, make up, lotions or aerosols inside of the clean room. No personal items are to be carried into the clean room. No one who is physically ill may enter the clean room. In addition, there are personal actions that are prohibited in the clean room including scratching head, combing hair, removing garments prior to gowning area, fast motions, improper changing of gloves, etc. Management of housekeeping is an essential part of the overall cleanliness of any clean room. There are required procedures for each class of clean room. For example, a Class 100 clean room requires the wiping down of walls and trim to be preformed on a weekly basis. A Class 1000 clean room may have more rigorous housekeeping regulations such as, using a DI cleaner (De-ionized water) and an approved wet mop to clean up to 2 times per shift.


Product Tags:

ISO8 Laboratory Cleanroom

      

SUSQ195 Laboratory Cleanroom

      

3843m3/H HEPA Clean room

      
Quality Modular ISO8 SUSQ195 Laboratory Cleanroom HEPA Filter 3843m3/H wholesale

Modular ISO8 SUSQ195 Laboratory Cleanroom HEPA Filter 3843m3/H Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Anlai Airtech Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)